The Manual Helium Leak Detection Equipment is a high-sensitivity helium leak detection device, mainly composed of a micro detection sensing unit, sampling probe, small pumping module, manual control valve, and digital display detection and alarm module. It features a simplified structure, portability, and easy operation, requiring no complex automated supporting devices — the entire leak detection process can be completed through manual operation.
The equipment is equipped with a high-precision helium-specific detection sensing core. Relying on the helium-specific detection principle, it can precisely capture trace helium leakage signals with high detection accuracy and fast response speed. It can stably adapt to various leak detection conditions including positive pressure and negative pressure, and is compatible with airtightness testing operations for various sealed cavities, pipelines, valves, and small components. This equipment offers stronger flexibility and mobility, adapting to diverse scenarios such as scattered workpiece sampling inspection in workshops, equipment maintenance leak checking, outdoor on-site testing, and precise locating of equipment fault points.
1. Equipment Capacity: CT = 550 UPH
2. Equipment Dimensions: L × W × H = 2000 × 1000 × 2500 mm
3. Equipment Escape Rate: 0%
4. Equipment Over-Kill Rate: ≤ 0.5%
5. Equipment Failure Rate: ≤ 1% (caused only by the equipment itself)
6. Equipment Features: Manual loading/unloading, automatic NG re-inspection, automatic code scanning (compatible), flexible and versatile, suitable for occasions with high site requirements.